Deodorization device removal - List of Manufacturers, Suppliers, Companies and Products

Deodorization device removal Product List

1~2 item / All 2 items

Displayed results

Improvement of working environment, compliance with emission standards, etc. - Chemical plant

Successfully captured over 95% of formaldehyde!

Since it is emitted along with dangerous exhaust gases such as carbon disulfide and hydrogen sulfide, which do not dissolve in water, caution is required due to the risk of corrosion and explosion. As a result of the installation of the deodorizer, it was possible to reduce formaldehyde from several tens of ppm to a single digit.

  • Drainage and ventilation equipment
  • Gas equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Wastewater Treatment Equipment (Fishing Port)

A case where the sewage odor caused by inflowing wastewater was removed using a deodorization device filled with the deodorization filter "Corline."

Hydrogen sulfide was generated in the wastewater treatment facility at the fishing port, causing corrosion of the control panel in the nearby electrical room. Even though the entire electrical room was sealed to prevent hydrogen sulfide from entering, the concentration of hydrogen sulfide did not decrease sufficiently. According to the measurement results, the hydrogen sulfide concentration was 6 ppb, and we received an inquiry about wanting to reduce this to below 1 ppb. After installing a demo unit of our product "Coraline" and confirming its effectiveness, they made a purchase. Currently, they are also considering its introduction to facilities nationwide. 【Case Summary】 ■ Installation Location: Wastewater Treatment Facility (Fishing Port) ■ Product Installed: Coraline ■ Challenges - Hydrogen sulfide was generated in the facility, causing corrosion of the control panel in the nearby electrical room - Even with the entire electrical room sealed, the hydrogen sulfide concentration did not decrease sufficiently - The hydrogen sulfide concentration was 6 ppb, and they wanted to reduce it to below 1 ppb *For more details, please refer to the PDF document or feel free to contact us.

  • Air conditioning equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration